Your SmartPLS model may have acceptable factor loadings and average variance extracted (AVE), yet two constructs can still be too similar to distinguish. That is the problem the heterotrait–monotrait ratio of correlations (HTMT) helps identify. This guide explains what the statistic means, how to read the SmartPLS 4 output and what to do when a result is above the chosen threshold. It uses an explicitly hypothetical example rather than claiming to analyse an actual dataset.
What Does HTMT Measure?
HTMT is a discriminant-validity assessment for reflectively measured constructs. It compares correlations between indicators of different constructs (heterotrait correlations) with correlations among indicators measuring the same construct (monotrait correlations). If two constructs are genuinely distinct, their indicators should not behave as though they measure the same thing.
Imagine a questionnaire about sustainable fashion. Knowledge of Sustainable Purchase asks whether students understand responsible clothing choices. Sustainable Consumption Behaviour asks what they report doing when shopping. These ideas may be related, but the measurement items should not collapse into one indistinguishable concept. A high HTMT value is a warning that the two sets of indicators overlap empirically.
Henseler, Ringle and Sarstedt (2015) introduced HTMT because traditional checks, particularly the Fornell–Larcker criterion and cross-loadings, can miss discriminant-validity problems in common situations. The original paper is available at Journal of the Academy of Marketing Science (DOI).
HTMT Thresholds: Is 0.85 or 0.90 Acceptable?
| HTMT value | Practical reading | What to report |
|---|---|---|
| 0.82 | Below both commonly used cut-offs | Supports discriminant validity by the threshold check |
| 0.88 | Above 0.85 but below 0.90 | Acceptability depends on the justified criterion and conceptual similarity |
| 0.93 | Above 0.90 | Potential discriminant-validity problem requiring investigation |
The official SmartPLS threshold guide marks HTMT values at or below 0.85 as the stricter range, values above 0.85 through 0.90 as a caution range, and values above 0.90 as problematic. Its discriminant-validity documentation also explains the commonly applied 0.90 criterion. Choose and justify the criterion in relation to your constructs and research literature; do not switch thresholds after seeing the results merely to obtain a pass.
How to Find HTMT Results in SmartPLS 4
- Open your project and confirm which constructs are reflective. HTMT is intended for discriminant-validity assessment of reflective measurement models, not a substitute for evaluating formative indicators.
- Run the PLS-SEM algorithm for your specified model.
- Open the results report and locate Quality Criteria → Discriminant Validity → HTMT (the exact display can vary by software release).
- Read each off-diagonal construct pair. Compare the value with the threshold you justified before interpreting the model.
- Record problematic pairs rather than reporting only the largest or smallest value.
SmartPLS calculates a variant commonly described as HTMT+, using absolute indicator correlations. Its documentation notes that this implementation differs from the original signed-correlation formula. Therefore, when comparing results calculated in different packages or manually, first check that the computational definitions match.
Worked HTMT Example: Three Reflective Constructs
Suppose a researcher models Environmental Concern (EC), Sustainable Purchase Knowledge (SPK) and Sustainable Buying Behaviour (SBB). All values below are fictional teaching examples.
| Construct pair | HTMT | Decision with 0.85 | Decision with 0.90 |
|---|---|---|---|
| EC – SPK | 0.74 | Below threshold | Below threshold |
| EC – SBB | 0.83 | Below threshold | Below threshold |
| SPK – SBB | 0.91 | Above threshold | Above threshold |
The first two pairs meet both cut-offs. SPK and SBB, however, show possible measurement overlap. A responsible interpretation would say that the SPK–SBB pair does not meet the chosen discriminant-validity criterion. It would not say that the entire model is invalid, nor quietly remove items until the statistic falls below 0.90.
How to Test HTMT with Bootstrapping
A point estimate alone does not show how much sampling uncertainty surrounds HTMT. SmartPLS supports bootstrap-based inference. Its official procedure for HTMT inference recommends choosing Calculate → Bootstrapping, selecting Complete (slower) for the amount of results, and a one-tailed test. Inspect the upper bound of the bias-corrected confidence interval for HTMT against the preselected critical value (for example, 0.90). See the SmartPLS HTMT inference instructions.
For final reporting, the SmartPLS bootstrapping documentation discusses large resampling counts, commonly around 10,000, to improve the stability of interval estimates. Record your actual subsample count, confidence level, interval method, test direction and software version. Do not treat the path-coefficient p-value as an HTMT test.
A confidence-interval example
| Hypothetical pair | Point HTMT | Upper 95% confidence bound | Interpretation against 0.90 |
|---|---|---|---|
| EC – SBB | 0.83 | 0.88 | Upper bound below 0.90; supports the chosen criterion |
| SPK – SBB | 0.89 | 0.94 | Upper bound exceeds 0.90; inference does not establish separation |
Notice the second pair: even though its point estimate is below 0.90, its upper confidence bound is not. A statement such as “all HTMT values are below 0.90, therefore discriminant validity is established” would overlook this uncertainty. Also, a confidence interval that extends beyond a threshold is not by itself proof that two theoretical constructs are identical.
What to Do When HTMT Is Too High
- Review construct definitions. Are the two constructs conceptually different, or are they alternative names for nearly the same phenomenon?
- Inspect item wording. Items such as “I know how to buy sustainable clothes” and “I buy sustainable clothes because I know how” may blend knowledge and behaviour. Review content validity before changing any items.
- Check cross-loadings and item-level correlations diagnostically. These can reveal ambiguous indicators, but they do not replace HTMT.
- Investigate data and coding. Verify reverse-coded items, duplicate columns, inconsistent response scales and other preparation errors.
- Consider theoretically defensible respecification. A higher-order construct or revised measurement instrument may be appropriate if theory supports it. Document changes and, where possible, validate them with fresh data.
Do not delete an indicator solely because it produces a convenient HTMT value. Deletion can narrow a construct’s content, bias comparisons and weaken the theoretical contribution. If the data were collected once using the same self-report questionnaire, discuss possible common-method influences and other limitations instead of claiming that HTMT alone diagnoses them.
HTMT vs AVE vs Fornell–Larcker: Which Question Does Each Answer?
| Criterion | Main question | Important limitation |
|---|---|---|
| AVE | Does a reflective construct explain sufficient variance in its indicators? | Convergent validity, not a direct test of separation between constructs |
| Fornell–Larcker | Is the square root of AVE larger than relevant construct correlations? | Can fail to detect overlap in some situations |
| HTMT | Are two reflective constructs empirically distinguishable? | Threshold and interval decisions still require theory and sound measurement |
For a broader introduction to structural-equation-model reporting, read the site’s SEM results and APA reporting guide. For the earlier steps in choosing an appropriate quantitative method, see analytical techniques for PhD research and regression interpretation.
Sample APA-Style Reporting Paragraph
Illustrative wording, not a real study: “Discriminant validity of the reflective constructs was assessed using the heterotrait–monotrait ratio (HTMT; Henseler et al., 2015). The prespecified criterion was HTMT < 0.90. The hypothetical EC–SPK and EC–SBB estimates were 0.74 and 0.83, respectively. The SPK–SBB estimate was 0.91 and therefore exceeded the criterion, suggesting insufficient discriminant validity for that construct pair. The measurement specification requires theoretical and item-level review before substantive path interpretation.”
If you also ran HTMT inference, add the confidence-interval method and the actual upper bounds. Report all construct pairs in a numbered table, identify abbreviations in a table note, and distinguish threshold evidence from statistical inference. The exact wording should reflect your own data, not these illustrative numbers.
Frequently Asked Questions
Can HTMT be 0.88 and still be acceptable?
It may be defensible under a prespecified 0.90 criterion for conceptually similar constructs, but it fails a stricter 0.85 criterion. Examine the confidence interval and explain why the selected threshold is appropriate.
Does a good SRMR mean discriminant validity is established?
No. SRMR concerns discrepancies between observed and model-implied correlations, whereas HTMT examines separation between reflectively measured constructs. A model can have a seemingly acceptable SRMR and still show problematic HTMT values. See the SmartPLS model-fit guidance.
Should I use HTMT for formative constructs?
Not as the standard discriminant-validity check used for reflective measurement. Formative measurement requires different evaluation, including content validity, indicator collinearity and the relevance of indicator weights.
References and Further Reading
- Henseler, J., Ringle, C. M., & Sarstedt, M. (2015). A new criterion for assessing discriminant validity in variance-based structural equation modeling. Journal of the Academy of Marketing Science, 43(1), 115–135. https://doi.org/10.1007/s11747-014-0403-8
- SmartPLS. (n.d.). Discriminant validity assessment. Official documentation.
- SmartPLS. (n.d.). Result colour thresholds. Official documentation.
- SmartPLS. (n.d.). Bootstrapping. Official documentation.